  input parameter conditions min. typ. max. units input voltage range 85 264 vac 100 400 vdc input frequency 47 63 hz input current see model selection guide inrush current 115 vac 10.0 a pk 230 vac 20.0 standby power 0.3 w output parameter conditions min. typ. max. units output voltage see model selection guide output current see model selection guide output voltage accuracy, see note 1 see model selection guide line regulation v in = min to max ?.5 % load regulation i out = 5% to 100% ?.5 % ripple & noise (20 mhz) 5v, 24v models 100 150 mv p-p 9v, 12v, 15v models 80 120 hold-up time 230 vac 50 msec temperature coef cient ?.01 %/? short circuit protection continuous (autorecovery) over temperature protection 150 ? general parameter conditions min. typ. max. units isolation voltage input to output 3,000 vac switching frequency 50 khz emi characteristics parameter standard min. typ. max. units radiated emissions see note 3 en 55022 class a conducted emissions see note 3 en 55022 class a esd en 61000-4-2 criteria b; ? kv contact rs see note 4 en 61000-4-3 criteria a; 10v/m eft see note 5 en 61000-4-4 criteria b; ? kv surge see note 6 en 61000-4-5 criteria b; ? kv /? kv cs see note 7 en 61000-4-6 criteria a; 3 vrms pfmf en 61000-4-8 criteria a; 10a/m voltage dips en 61000-4-11 criteria b; 0% - 70% environmental parameter conditions min. typ. max. units operating temperature range ambient -40 +25 +85 ? operating temperature range case +90 ? storage temperature range -40 +105 ? cooling free air convection (see derating curve) humidity rh, non-condensing 85 % physical case size 1.38 x 0.43 x 0.94 inches (35.0 x 11.0 x 24.0 mm) case material non-conductive epoxy (ul94-v0) weight 0.35 oz (10g) reliability speci cations parameter conditions min. typ. max. units mtbf mil hdbk 217f, 25?, gnd benign 300 khours safety standards en 60950 safety class iec 61140 class ii single output, 1w ultra-miniature sip ac/dc power supplies key features: 1w output power universal 85-264 vac input en 60950 approved (ul) meets iec safety class ii single regulated output meets en 55022 class a >300 khour mtbf ultra-miniature ?sip? case MPL-01SE series electrical speci cations speci cations typical @ +25?, 230 vac input voltage & rated output current, unless otherwise noted. speci cations subject to change without notice. micropower direct 292 page street suite d stoughton, ma 02072 usa t: (781) 344-8226 f: (781) 344-8481 e: sales@micropowerdirect.com w: www.micropowerdirect.com www.micropowerdirect.com
model selection guide notes: all dimensions are typical in inches (mm) tolerance x.xx = 0.02 ( 0.50) pin function pin function 1 ac-neutral 7 -v cap 3 ac-line 10 -v out 5+v cap 12 +v out pin connections model number input output output voltage accuracy (%) ef ciency (%, typ) current (a) voltage (vdc) current (ma max.) 115 vac 230 vac mpl-01s-05e 0.120 0.060 5.0 200 ?.0 66 mpl-01s-09e 0.120 0.060 9.0 111 ?.0 67 mpl-01s-12e 0.120 0.060 12.0 83.3 ?.0 70 mpl-01s-15e 0.120 0.060 15.0 66.6 ?.0 69 mpl-01s-24e 0.120 0.060 24.0 41.6 ?.0 68 derating curve mechanical dimensions micropower direct we power your success - for less! 292 page street ste d stoughton, ma 02072 tel: (781) 344-8226 fax: (781) 344-8481 e-mail: sales@micropowerdirect.com www.micropowerdirect.com typical connection 1. it is recommended that an external fuse and ntc be used. the recommended fuse is a 1.0a/250v slow blow and for the ntc, a 5d-9. 2. an external mov is recommended on the input to protect the unit in the event of a surge. a 561kd14 or equivalent is recommended. 3. the lter capacitor c 1 is required for emc performance over the full input range. the recommended value is 10 to 22 f/400v. 4. recommended output ltering capacitors are: c 2 c 3 tvs mpl-01s-05e 1.0 f/50v 470 f/35v smbj7.0a mpl-01s-09e 1.0 f/50v 150 f/35v smbj12a mpl-01s-12e 1.0 f/50v 150 f/35v smbj20a mpl-01s-15e 1.0 f/50v 150 f/35v smbj20a mpl-01s-24e 1.0 f/50v 100 f/35v smbj30a the output ltering capacitor (c 3 ) is a high frequency, low resistance electrolytic capacitor. capacitor (c 2 ) is ceramic. voltage derating of capacitors should be 80% or above. 5. input noise and surge suppression modules are available for a number of mpd ac/dc power supplies. an MPL-01SE connection with the a cfm-01 is illustrated in the diagram at left. for pricing or full technical information on these modules ( acfm-01 and acfm-02 ) please contact the factory. notes: 1. for the 5v output model, accuracy is ?0% over the -40 c to +85 c temperature range. 2. operation at no load will not damage the units, however, they may not meet all speci cations. 3. all units are rated for en 55022 (ce/re) class a without external components. they will meet class b with the addition of the acfm-01 (or a similar discrete lter circuit). contact the factory for more information. 4. to meet the requirements of en 61000-4-3, (10v/m) external components are needed. this can be done discretely, or with t he addition of the acfm-01 . contact the factory for more information. 5. to meet the requirements of en 61000-4-4 ( ? kv), external components are needed. this can be done discretely, or with t he addition of the acfm-01 . contact the factory for more information. 6. to meet the requirements of en 61000-4-5 ( ? kv/? kv), external components are needed. this can be done discretely, or with the addition of the acfm-01 . contact the factory for more information. 7. to meet the requirements of en 61000-4-6 (3v rms), external components are needed. this can be done discretely, or with t he addition of the acfm-01 . contact the factory for more information. 8. it is recommended that a fuse be used on the input of a power supply for protection. for the MPL-01SE series, a 1.0a/250 vac slow blow should be used. input voltage vs load the diagram below illustrates a typical application connection of the MPL-01SE series. notes on this circuit (starting with the input circuit) are: typical board layout : with acfm-01 input module (see note 5)


▲Up To Search▲   

 
Price & Availability of MPL-01SE

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X